Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 153
Filtrar
2.
J Prosthodont Res ; 63(1): 100-104, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30385331

RESUMO

PURPOSE: To evaluate the influence of the preparation design and spacing parameters on the risk of chipping of crowns made by CEREC Bluecam before cementation. METHODS: A knife-edge preparation and a chamfer preparation were made on upper premolars. The teeth were scanned and two Co-Cr alloy replicas were made. Fifteen full crowns were manufactured for four groups using CEREC. The groups differed in type of preparation (knife-edge (KE) or chamfer (CHA)) and spacing parameters: spacer (0 or 150µm), marginal adhesive gap (10 or 50 or 150µm) and margin thickness (0 or 300µm). The four groups were: CHA 150 (spacer)- 50 (marginal adhesive gap)- 0 (margin thickness), KE 150-50-0, KE 150-50-300 and KE 150-150-300. The crowns were loaded before cementation by using an Instron machine to simulate the masticatory load applied during a trial. Differences in means were compared using two-way ANOVA and a post-hoc test (Tukey Test). The level of significance was set at P=0.05. RESULTS: The fracture values, ordered from least to most resistant, were: KE 150-50-300 group, CHA 150-50-0 group, KE 150-50-0 group and KE 150-150-300 group. Two-way ANOVA revealed statistically significant differences between pairs of means (p<0.05). Tukey's test showed that restorations of the KE 150-150-300 group can withstand a load significantly higher than that of other groups (p<0.01). In this group, the failures were mostly minor chippings, while the other groups had mostly major chippings and fractures. CONCLUSIONS: Marginal adhesive gap can affect the trial of a full crown.


Assuntos
Cimentação , Resinas Compostas , Coroas , Adaptação Marginal Dentária , Planejamento de Prótese Dentária/métodos , Falha de Restauração Dentária , Cimentos de Resina , Desenho Assistido por Computador , Análise do Estresse Dentário , Risco
3.
Oper Dent ; 42(5): E121-E133, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28829934

RESUMO

OBJECTIVE: To evaluate the effect of different methods of silica deposition on the intaglio surface of yttrium oxide stabilized zirconia polycrystal (Y-TZP) crowns on the retentive strength of the crowns. METHODS: One hundred simplified full-crown preparations produced from fiber-reinforced polymer material were scanned, and 100 Y-TZP crowns with occlusal retentions were milled. Crown/preparation assemblies were randomly allocated into five groups (n=20) according to the treatment of the intaglio surfaces: TBS = tribochemical silica coating via air-abrasion with 30-µm silica-coated alumina particles; GHF1 = application of thin glaze layer + hydrofluoric acid (HF) etching for 1 minute; GHF5 = glaze application + HF for 5 minutes; GHF15 = glaze application + HF for 15 minutes; NANO = silica nanofilm deposition (5 nm) via magnetron sputtering. All groups received a silane application. The surfaces of the preparations (polymer) were conditioned with 10% HF for 30 seconds and silanized. The crowns were cemented with resin cement, thermocycled (12,000 cycles; 5°C/55°C), stored for 60 days, and subjected to a retentive strength test (0.5 mm/min until failure). The retention data (MPa) were analyzed using one-way analysis of variance, Tukey tests, and Weibull analysis. Failures were classified as 50C (above 50% of cement in the crown) and 50S (above 50% of cement on the substrate). RESULTS: The TBS (5.6±1.7 MPa) and NANO groups (5.5±1 MPa) had higher retentive strength than the other groups (p<0.0001) and had the highest values of characteristic strength. There was no difference in Weibull modulus, except for the GHF1 group (lower values). The TBS and GHF15 groups, respectively, had 60% and 70% of their failures classified as 50C, while most of the other groups had 50S failures. CONCLUSION: Tribochemical silica coating and silica nanofilm deposition on the inner surface of zirconia crowns promoted a higher retentive strength.


Assuntos
Coroas , Dióxido de Silício/administração & dosagem , Ítrio , Zircônio , Colagem Dentária/métodos , Retenção em Prótese Dentária/métodos , Falha de Restauração Dentária , Análise do Estresse Dentário , Humanos
4.
Colloids Surf B Biointerfaces ; 157: 26-30, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28570988

RESUMO

This study aims to deepen the knowledge on tear film properties by the development of a protocol for analyses of Photon Correlation Spectroscopy (PCS) on human tears and by the comparison between PCS results obtained on tears of contact lens wearers and non-wearers. Tears (5µL) were collected by a glass capillary. The analyses provide the hydrodynamic diameter of tear components by analyzing intensity fluctuations in time of scattered light. PCS appears a promising technique for studying tear features and for shedding light on specific eye conditions, such as on the clinical effects of CL wear. In fact, statistical difference (p<0.001) was found between the measured mean hydrodynamic diameter of tear components of wearers and non-wearers, the resulting value significantly higher for CL wearers. The scenario does not substantially change after (25±5)min from the CL removal. The difference is attributed to changes in the interactions between tear constituents due to CL wear. In order to get deeper insights on the influence of CL wear on aggregation and structure of tear components, a preliminary Electron Spin Resonance (ESR) investigation was performed, monitoring Fe3+ species. ESR spectra on tears of both CL wearers and non-wearers showed the presence of intense signals, probably associated to iron (III) centers in proteins such as lactoferrin, and a weaker resonance attributable to Fe3+ species interacting with S-S bridges of lysozyme. Differences in ESR spectra between CL wearers and non-wearers were detected and tentatively ascribed to changes in coordination or in local environment of Fe3+ centers connected to aggregation phenomena induced by CL wear, which promote their interaction with other neighboring iron species.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Lágrimas/química , Adulto , Lentes de Contato , Feminino , Humanos , Hidrodinâmica , Masculino
5.
Oper Dent ; 42(4): 436-444, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28402732

RESUMO

The aim of this study was to evaluate the effect of different production methods of resin and ceramic inlays on marginal and internal adaptation, adjustment time, and proximal contacts. Forty premolars were selected, embedded (their roots), and prepared to receive inlays that were made as follows (n=10): LaRe-digital impression with a Lava C.O.S. scanner, followed by milling of Lava Ultimate block (composite resin) in a milling center; CeRe-digital impression with a Cerec 3D Bluecam scanner, followed by milling of Lava Ultimate block in Cerec; CeDis-digital impression with a Cerec 3D Bluecam scanner, followed by milling of IPS e.max CAD block (lithium disilicate) in Cerec; and PresDis-impression with polyvinyl siloxane, inlay made using the lost wax technique and IPS e.max Press pressed ceramic (lithium disilicate). Marginal and internal adaptations were measured using the replica technique. The inlay adjustments were performed using diamond burs in a contra-angle hand piece, and the time for adjustment was recorded using a timer, in seconds. The tightness of the proximal contact was measured using standardized metal blades. The statistical analyses for marginal fit data showed that at the cervical edge, CeDis (177.8 µm) had greater misfit than CeRe (116.7 µm), while all the groups had similar adaptation at the occlusal edge. The groups had similar internal fit at the pulpal wall, while LaRe (104.7 µm) > CeDis (66.7 µm) = CeRe (76.7 µm) at the axial wall. The groups restored with lithium disilicate ceramic took more time for adjustment when compared to the resin restorative material. The lowest proximal contact, in micrometers, was seen in the CeRe group (8.8 µm).


Assuntos
Resinas Compostas/química , Técnica de Moldagem Odontológica , Adaptação Marginal Dentária , Porcelana Dentária/química , Restaurações Intracoronárias , Dente Pré-Molar , Preparo da Cavidade Dentária , Materiais Dentários/química , Humanos , Técnicas In Vitro , Teste de Materiais , Fatores de Tempo
6.
J Biomed Mater Res B Appl Biomater ; 105(4): 723-734, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-26708554

RESUMO

Three-dimension (3D) scaffolds for bone tissue regeneration were produced combining three different phases: nanometric hydroxyapatite (HA) was synthesized by precipitation method and the crystals nucleation took place directly within collagen fibrils following a biologically inspired mineralization process; polycaprolactone was employed to give the material a 3D structure. The chemico-physical analysis carried out to test the material's properties and composition revealed a high similarity in composition and morphology with biologically mineralized collagen fibrils and a scaffold degradation pattern suitable for physiological processes. The micro- computerized tomography (micro-CT) showed 53.53% porosity and a 97.86% mean interconnected pores. Computer-aided design and computer-aided manufacturing (CAD-CAM) technology was used for molding the scaffold's volume (design/shape) and for guiding the surgical procedure (cutting guides). The custom made scaffolds were implanted in sheep mandible using prototyped surgical guides and customized bone plates. After three months healing, scanning electron microscopy (SEM) analysis of the explanted scaffold revealed a massive cell seeding of the scaffold, with cell infiltration within the scaffold's interconnected pores. The micro-CT of the explanted construct showed a good match between the scaffold and the adjacent host's bone, to shield the implant primary stability. Histology confirmed cell penetration and widely documented neoangiogenesis within the entire scaffold's volume. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 723-734, 2017.


Assuntos
Materiais Biomiméticos/química , Regeneração Óssea , Substitutos Ósseos/química , Durapatita/química , Mandíbula , Traumatismos Mandibulares , Alicerces Teciduais/química , Animais , Mandíbula/diagnóstico por imagem , Mandíbula/metabolismo , Traumatismos Mandibulares/diagnóstico por imagem , Traumatismos Mandibulares/metabolismo , Traumatismos Mandibulares/terapia , Teste de Materiais , Ovinos , Microtomografia por Raio-X
8.
Scand J Rheumatol ; 45(2): 135-45, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26398142

RESUMO

OBJECTIVES: To describe the clinical features, treatment response, and follow-up of a large cohort of Italian patients with immunoglobulin (Ig)G4-related disease (IgG4-RD) referred to a single tertiary care centre. METHOD: Clinical, laboratory, histological, and imaging features were retrospectively reviewed. IgG4-RD was classified as 'definite' or 'possible' according to international consensus guidelines and comprehensive diagnostic criteria for IgG4-RD. Disease activity was assessed by means of the IgG4-RD Responder Index (IgG4-RD RI). RESULTS: Forty-one patients (15 females, 26 males) were included in this study: 26 with 'definite' IgG4-RD and 15 with 'possible' IgG4-RD. The median age at diagnosis was 62 years. The median follow-up was 36 months (IQR 24-51). A history of atopy was present in 30% of patients. The pancreas, retroperitoneum, and major salivary glands were the most frequently involved organs. Serum IgG4 levels were elevated in 68% of cases. Thirty-six patients were initially treated with glucocorticoids (GCs) to induce remission. IgG4-RD RI decreased from a median of 7.8 at baseline to 2.9 after 1 month of therapy. Relapse occurred in 19/41 patients (46%) and required additional immunosuppressive drugs to maintain long-term remission. Multiple flares occurred in a minority of patients. A single case of orbital pseudotumour did not respond to medical therapy and underwent surgical debulking. CONCLUSIONS: IgG4-RD is an elusive inflammatory disease to be considered in the differential diagnosis of isolated or multiple tumefactive lesions. Long-term disease control can be achieved with corticosteroids and immunosuppressive drugs in the majority of cases.


Assuntos
Doenças Autoimunes/imunologia , Glucocorticoides/uso terapêutico , Imunoglobulina G/imunologia , Imunossupressores/uso terapêutico , Pancreatite/imunologia , Sialadenite/imunologia , Idoso , Doenças Autoimunes/complicações , Doenças Autoimunes/tratamento farmacológico , Estudos de Coortes , Procedimentos Cirúrgicos de Citorredução , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Pseudotumor Orbitário/etiologia , Pseudotumor Orbitário/imunologia , Pseudotumor Orbitário/cirurgia , Pancreatite/tratamento farmacológico , Pancreatite/etiologia , Recidiva , Indução de Remissão , Espaço Retroperitoneal , Estudos Retrospectivos , Sialadenite/tratamento farmacológico , Sialadenite/etiologia
9.
Acta Otorhinolaryngol Ital ; 35(3): 198-201, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26246665

RESUMO

Free fibula flap is routinely used for mandibular reconstructions. For contouring the flap, multiple osteotomies should be shaped to reproduce the native mandibular contour. The bone segments should be fixed using a reconstructive plate. This plate is usually manually bent by the surgeon during surgery. This method is efficient, but during reconstruction it is complicated to reproduce the complex 3D conformation of the mandible and recreate a normal morphology with a mandibular profile as similar as possible to the original; any aberration in its structural alignment may lead to aesthetic and function alterations due to malocclusion or temporomandibular disorders. In order to achieve better morphological and functional outcomes, we have performed a customised flap harvest using cutting guides. This study demonstrates how we have performed customised mandibular reconstruction using CAD-CAM fibular cutting guides in 20 patients undergoing oncological segmental resection.


Assuntos
Desenho Assistido por Computador , Fíbula/transplante , Retalhos de Tecido Biológico , Reconstrução Mandibular/métodos , Coleta de Tecidos e Órgãos/métodos , Humanos
10.
Soft Matter ; 11(20): 4022-33, 2015 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-25899456

RESUMO

Silica-styrene butadiene rubber (SBR) nanocomposites were prepared by using shape-controlled spherical and rod-like silica nanoparticles (NPs) with different aspect ratios (AR = 1-5), obtained by a sol-gel route assisted by a structure directing agent. The nanocomposites were used as models to study the influence of the particle shape on the formation of nanoscale immobilized rubber at the silica-rubber interface and its effect on the dynamic-mechanical behavior. TEM and AFM tapping mode analyses of nanocomposites demonstrated that the silica particles are surrounded by a rubber layer immobilized at the particle surface. The spherical filler showed small contact zones between neighboring particles in contact with thin rubber layers, while anisotropic particles (AR > 2) formed domains of rods preferentially aligned along the main axis. A detailed analysis of the polymer chain mobility by different time domain nuclear magnetic resonance (TD-NMR) techniques evidenced a population of rigid rubber chains surrounding particles, whose amount increases with the particle anisotropy, even in the absence of significant differences in terms of chemical crosslinking. Dynamic measurements demonstrate that rod-like particles induce stronger reinforcement of rubber, increasing with the AR. This was related to the self-alignment of the anisotropic silica particles in domains able to immobilize rubber.

11.
Oper Dent ; 40(1): E1-E10, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25162722

RESUMO

This study evaluated the effect of the cement type (adhesive resin, self-adhesive, glass ionomer, and zinc phosphate) on the retention of crowns made of yttria-stabilized polycrystalline tetragonal zirconia (Y-TZP). Therefore, 108 freshly extracted molars were embedded in acrylic resin, perpendicular to their long axis, and prepared for full crowns: the crown preparations were removed and reconstructed using composite resin plus fiber posts with dimensions identical to the prepared dentin. The preparations were impressed using addition silicone, and Y-TZP copings were produced, which presented a special setup for the tensile testing. Cementation was performed with two adhesive resin cements (Multilink Automix, Ivoclar-Vivadent; RelyX ARC, 3M ESPE, St Paul, MN, USA), one self-adhesive resin cement (RelyX U100, 3M ESPE), one glass ionomer based cement (RelyX Luting, 3M ESPE), and one zinc phosphate cement (Cimento de Zinco, SS White, Rio de Janeiro, Brazil). For the resin cement groups, the inner surfaces of the crowns were subjected to three surface treatments: cleaning with isopropyl alcohol, tribochemical silica coating, or application of a thin low-fusing glass porcelain layer plus silanization. After 24 hours, all groups were subjected to thermocycling (6000 cycles) and included in a special device for tensile testing in a universal testing machine to test the retention of the infrastructure. After testing, the failure modes of all samples were analyzed under a stereomicroscope. The Kruskal-Wallis test showed that the surface treatment and cement type (α=0.05) affected the tensile retention results. The Multilink cement presented the highest tensile retention values, but that result was not statistically different from RelyX ARC. The surface treatment was statistically relevant only for the Multilink cement. The cement choice was shown to be more important than the crown surface treatment for cementation of a Y-TZP crown to a composite resin substrate.


Assuntos
Coroas , Cimentos de Resina/uso terapêutico , Ítrio/uso terapêutico , Zircônio/uso terapêutico , Bis-Fenol A-Glicidil Metacrilato/uso terapêutico , Coroas/normas , Corrosão Dentária , Falha de Restauração Dentária , Análise do Estresse Dentário , Cimentos de Ionômeros de Vidro/uso terapêutico , Humanos , Fosfatos/uso terapêutico , Polietilenoglicóis/uso terapêutico , Ácidos Polimetacrílicos/uso terapêutico , Resinas Sintéticas/uso terapêutico , Resistência à Tração , Compostos de Zinco/uso terapêutico
12.
Biomed Res Int ; 2013: 549762, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24073409

RESUMO

PURPOSE: This study evaluated the efficacy of a regenerative approach using mesenchymal stem cells (MSCs) and CAD-CAM customized pure and porous hydroxyapatite (HA) scaffolds to replace the temporomandibular joint (TMJ) condyle. METHODS: Pure HA scaffolds with a 70% total porosity volume were prototyped using CAD-CAM technology to replace the two temporomandibular condyles (left and right) of the same animal. MSCs were derived from the aspirated iliac crest bone marrow, and platelets were obtained from the venous blood of the sheep. Custom-made surgical guides were created by direct metal laser sintering and were used to export the virtual planning of the bone cut lines into the surgical environment. Sheep were sacrificed 4 months postoperatively. The HA scaffolds were explanted, histological specimens were prepared, and histomorphometric analysis was performed. RESULTS: Analysis of the porosity reduction for apposition of newly formed bone showed a statistically significant difference in bone formation between condyles loaded with MSC and condyles without (P < 0.05). The bone ingrowth (BI) relative values of split-mouth comparison (right versus left side) showed a significant difference between condyles with and without MSCs (P < 0.05). Analysis of the test and control sides in the same animal using a split-mouth study design was performed; the condyle with MSCs showed greater bone formation. CONCLUSION: The split-mouth design confirmed an increment of bone regeneration into the HA scaffold of up to 797% upon application of MSCs.


Assuntos
Plaquetas/química , Cerâmica/farmacologia , Desenho Assistido por Computador , Durapatita/farmacologia , Côndilo Mandibular/fisiologia , Células-Tronco Mesenquimais/citologia , Alicerces Teciduais/química , Animais , Cartilagem/citologia , Cartilagem/efeitos dos fármacos , Géis , Côndilo Mandibular/efeitos dos fármacos , Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais/efeitos dos fármacos , Células-Tronco Mesenquimais/metabolismo , Porosidade , Ovinos , Engenharia Tecidual
13.
Dent Mater ; 29(4): e45-52, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23395426

RESUMO

OBJECTIVES: To evaluate flexural properties of different fiber posts systems and to morphologically characterize their micro-structure. METHODS: Six types of translucent fiber posts were selected: RelyX Post (3M ESPE), ParaPost Taper Lux (Colthéne-Whaledent), GC Fiber Post (GC), LuxaPost (DMG), FRC Postec Plus (Ivoclar-Vivadent), D.T. Light-Post (RTD). For each post system and size, ten specimens were subjected to a three-points bending test. Maximum fracture load, flexural strength and flexural modulus were determined using a universal loading device (5848 MicroTester(®), Instron). Besides, for each system, three intact posts of similar dimensions were processed for scanning electron microscopy to morphologically characterize the micro-structure. The following structural characteristics were analyzed: fibers/matrix ratio, density of fibers, diameter of fibers and distribution of fibers. Data were statistically analyzed with ANOVA. RESULTS: Type and diameter of posts were found to significantly affect the fracture load, flexural strength and flexural modulus (p<0.05). Regarding maximum fracture load, it was found to increase with post diameter, in each post system (p<0.001). Regarding flexural strength and flexural modulus, the highest values were recorded for posts with the smallest diameter (p<0.001). Finally, structural characteristics significantly varied among the post systems tested. However, any correlation has been found between flexural strength and structural characteristics. SIGNIFICANCE: Flexural strength appeared not to be correlated to structural characteristics of fiber posts, but it may rather be affected by mechanical properties of the resin matrix and the interfacial adhesion between fibers and resin matrix.


Assuntos
Materiais Dentários/química , Vidro/química , Técnica para Retentor Intrarradicular , Análise de Variância , Análise do Estresse Dentário , Módulo de Elasticidade , Análise de Falha de Equipamento , Teste de Materiais , Microscopia Eletrônica de Varredura , Resinas Sintéticas/química , Propriedades de Superfície
14.
J Dent ; 41(3): 207-15, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23069329

RESUMO

OBJECTIVES: To evaluate the influence of the ferrule effect (1) and the fibre-post placement (2) on the fracture resistance of endodontically treated teeth subjected to cyclic fatigue loading. METHODS: 40 extracted single-rooted upper pre-molars were sectioned at the CEJ (groups a and b) or 2mm above the CEJ (groups c and d), and subsequently endodontically treated. After 24-h water storage at 37°C, specimens were restored according to four build-up approaches (n=10 per group): (a) NF-NP (no ferrule, no post), (b) NF-P (no ferrule, fibre-post), (c) F-NP (ferrule, no post) and (d) F-P (ferrule, fibre post). RelyX Posts (3M-ESPE) were used in groups NF-P and F-P, and were cemented with Panavia F 2.0 (Kuraray). A standardized composite core was built, after which specimens were restored with an all-ceramic crown (IPS Empress CAD, Ivoclar-Vivadent) Specimens were fatigued by exposure to 1,200,000 cycles using a chewing simulator (Willytech). All specimens that survived fatigue loading were fractured using a universal loading device (Micro-Tester, Instron). A two-way analysis of variance was used to determine the statistical significance of the factors ferrule and post on fracture resistance. RESULTS: Only one NF-NP specimen failed under fatigue. The ferrule effect significantly enhanced the fracture resistance of the restored teeth, regardless the use of a post (p=0.003). F-NP obtained the highest fracture resistance (758.52±121.89N), which was not significantly different from F-P (647.58±132.95N); NF-NP presented the lowest fracture resistance (361.52±151.69N). For all groups, only 'repairable' failures were recorded. CONCLUSIONS: Avoiding extra-removal of sound tooth structure, rather than placing a fibre post, can protect endodontically treated teeth against catastrophic failure. However, when any ferrule can be preserved, a fibre-post may improve the retention and fatigue resistance of the restoration.


Assuntos
Técnica para Retentor Intrarradicular , Fraturas dos Dentes/etiologia , Dente não Vital , Análise de Variância , Análise do Estresse Dentário , Vidro , Humanos , Estatísticas não Paramétricas , Dente não Vital/complicações
15.
Artigo em Inglês | MEDLINE | ID: mdl-21923559

RESUMO

The protocol presented here is intended to minimise the intervention in bone reconstruction surgery when severe atrophy or deformity is present in the maxillary arches. A patient underwent augmentation of an atrophic maxillary arch using titanium mesh and particulate autogenous plus bovine demineralised bone. After computed tomography data elaboration, computer-aided design and computer-aided machining were used to plan the augmentation of bone volume to improve the implant position needed to support the final dental prosthesis. The augmented maxilla was rapidly prototyped in plastic, and the titanium mesh was tested on this model before the surgical intervention. Then, the preformed titanium mesh was implanted in the maxillary arch with bone grafting. The bone was augmented relative to the position of the implants for the definitive fixed implant-supported rehabilitation. The protocol presented here is a viable, reproducible way to determine the correct bone augmentation for the final implant-supported prosthetic rehabilitation.


Assuntos
Perda do Osso Alveolar/cirurgia , Regeneração Tecidual Guiada/métodos , Doenças Maxilares/cirurgia , Prótese Maxilofacial , Perda do Osso Alveolar/diagnóstico por imagem , Animais , Regeneração Óssea , Transplante Ósseo , Bovinos , Desenho Assistido por Computador , Humanos , Imageamento Tridimensional , Masculino , Doenças Maxilares/diagnóstico por imagem , Pessoa de Meia-Idade , Desenho de Prótese , Telas Cirúrgicas , Titânio , Tomografia Computadorizada por Raios X
16.
Med Biol Eng Comput ; 50(7): 743-9, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22447348

RESUMO

This paper describes a new protocol for mandibular reconstruction. Computer-aided design/computer-aided manufacturing (CAD/CAM) technology was used to manufacture custom-made cutting guides for tumor ablation and reconstructive plates to support fibula free flaps. CT scan data from a patient with an odontogenic keratocyst on the left mandibular ramus were elaborated to produce a virtual surgical plan of mandibular osteotomy in safe tissue for complete ramus resection. The CAD/CAM procedure was used to construct a customized surgical device composed of a cutting guide and a titanium reconstructive bone plate. The cutting guide allowed the surgeon to precisely transfer the virtual planned osteotomy into the surgical environment. The bone plate, including a custom-made anatomical condylar prosthesis, was designed using the outer surface of the healthy side of the mandible to obtain an ideal contour and avoid the bone deformities present on the side affected by the tumor. Operation time was reduced in the demolition and reconstruction phases. Functional and aesthetic outcomes allowed patients to immediately recover their usual appearance and functionality. This new protocol for mandibular reconstruction using CAD/CAM to construct custom-made guides and plates may represent a viable way to reproduce the patient's anatomical contour, give the surgeon better procedural control, and reduce operation time.


Assuntos
Placas Ósseas , Transplante Ósseo/métodos , Desenho Assistido por Computador , Côndilo Mandibular/cirurgia , Próteses e Implantes , Fíbula/transplante , Retalhos de Tecido Biológico , Humanos , Masculino , Doenças Mandibulares/cirurgia , Pessoa de Meia-Idade , Cistos Odontogênicos/cirurgia , Osteotomia/métodos , Desenho de Prótese
17.
J Dent ; 40(4): 312-21, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22285922

RESUMO

OBJECTIVES: To evaluate the effect of the length of fibre-posts(1) and type of adhesive cement(2) on the fracture resistance of endodontically treated teeth, after fatigue loading. METHODS: Eighty extracted upper pre-molars were sectioned at the CEJ and endodontically treated. After 24 h of water storage at 37°C, RelyX Posts (3M-ESPE) were cemented with Panavia F 2.0 (Kuraray) or RelyX Unicem (3M-ESPE). A standardized composite core was built. Specimens were divided into four groups depending on the post-core ratio: (A) 2/1 (control); (B) 3/2; (C) 1/1 (small diameter); (D) 1/1(large diameter) and submitted to 1,200,000 cycles using a chewing simulator (Willytech). Immediately afterwards, all specimens that survived fatigue loading were fractured using a universal loading device (Micro-tester, Instron). Data were analysed with ANOVA. RESULTS: Four percent of the specimens failed during fatigue loading. The length of the post into the root affected the fracture resistance. The statistical outcome varied according to the inclusion of specimens failed during fatigue loading. However, the control group always had the lowest fracture resistance. The type of adhesive cement did not affect the fracture resistance. A prevalence of not-repairable failures was observed in specimens restored with the longest posts, whilst shorter posts led to more repairable failures. CONCLUSIONS: Shortening the post length and the ensuing preservation of more tooth structure, offer the potential for reparability through an in-built fail safe mechanism and may thus reduce the occurrence of catastrophic failures.


Assuntos
Cimentação/métodos , Materiais Dentários/química , Planejamento de Prótese Dentária , Vidro/química , Técnica para Retentor Intrarradicular/instrumentação , Fraturas dos Dentes/fisiopatologia , Dente não Vital/terapia , Dente Pré-Molar/fisiopatologia , Força de Mordida , Resinas Compostas/química , Cimentos Dentários/química , Análise do Estresse Dentário/instrumentação , Adesivos Dentinários/química , Humanos , Teste de Materiais , Metacrilatos/química , Cimentos de Resina/química , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo , Dente não Vital/fisiopatologia , Água/química
18.
Dent Mater ; 28(3): 287-97, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22169674

RESUMO

OBJECTIVES: To evaluate the effect of different factors on the push-out bond strength of glass fiber posts luted in simulated (standard) root canals using different composite cements. METHODS: Three types of glass-fiber root-canal posts with a different matrix, namely an epoxy resin (RelyX post, 3M ESPE), a proprietary composite resin (FRC-Plus post, Ivoclar-Vivadent), and a methacrylate resin (GC post, GC), and three types of composite cements, namely an etch-and-rinse Bis-GMA-based (Variolink II, Ivoclar-Vivadent), a self-etch 10-MDP-based (Clearfil Esthetic Cement, Kuraray) and a self-adhesive (RelyX Unicem, 3M ESPE) cement, were tested. Posts were either left untreated (control), were treated with silane, or coated with silicated alumina particles (Cojet system, 3M ESPE). Posts were inserted up to 9-mm depth into composite CAD-CAM blocks (Paradigm, 3M ESPE) in order to solely test the strength of the cement-post interface, while excluding interference of the cement-dentin interface. After 1-week storage at 37 °C, three sections (coronal, middle, apical) of 2-mm thickness were subjected to a push-out bond-strength test. RESULTS: All three variables, namely the type of post, the composite cement and the post-surface pre-treatment, were found to significantly affect the push-out bond strength (p<0.001). Regarding the type of post, a significantly lower push-out bond strength was recorded for the FRC-Plus post (Ivoclar-Vivadent); regarding the composite cement, a significantly higher push-out bond strength was recorded for the self-adhesive cement Unicem (3M ESPE); and regarding the post-surface treatment, a significantly higher push-out bond strength was recorded when the post-surface was beforehand subjected to a Cojet (3M ESPE) combined sandblasting/silicatization surface pre-treatment. Many interactions between these three variables were found to be significant as well (p<0.001). Finally, the push-out bond strength was found to significantly reduce with depth from coronal to apical. SIGNIFICANCE: Laboratory testing revealed that different variables like the type of post, the composite cement and the post-surface pre-treatment may influence the cement-post interface, making clear guidelines for routine clinical practice hard to define. Further long-term durability testing may help to clarify, and should therefore be encouraged.


Assuntos
Cimentação/métodos , Colagem Dentária , Corrosão Dentária/métodos , Técnica para Retentor Intrarradicular , Cimentos de Resina/química , Resinas Acrílicas , Óxido de Alumínio , Análise de Variância , Materiais Revestidos Biocompatíveis , Resinas Compostas , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Resinas Epóxi , Vidro , Distribuição Aleatória , Silanos , Estatísticas não Paramétricas , Propriedades de Superfície
19.
Med Biol Eng Comput ; 49(11): 1347-52, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21779902

RESUMO

This study describes a protocol for the direct manufacturing of a customized titanium mesh using CAD-CAM procedures and rapid prototyping to augment maxillary bone and minimize surgery when severe atrophy or post-oncological deformities are present. Titanium mesh and particulate autogenous plus bovine demineralised bone were planned for patient rehabilitation. Bone augmentation planning was performed using the pre-op CT data set in relation to the prosthetic demands, minimizing the bone volume to augment at the minimum necessary for implants. The containment mesh design was used to prototype the 0.6 mm thickness customized titanium mesh, by direct metal laser sintering. The levels of regenerated bone were calculated using the post-op CT data set, through comparison with the pre-op CT data set. The mean vertical height difference of the crestal bone was 2.57 mm, while the mean buccal-palatal dimension of thickness difference was 3.41 mm. All planned implants were positioned after an 8 month healing period using two-step implant surgery, and finally restored with a partial fixed prosthesis. We present a viable and reproducible method to determine the correct bone augmentation prior to implant placement and CAD-CAM to produce a customized direct laser-sintered titanium mesh that can be used for bone regeneration.


Assuntos
Aumento do Rebordo Alveolar/instrumentação , Regeneração Óssea/fisiologia , Maxila/cirurgia , Doenças Maxilares/cirurgia , Telas Cirúrgicas , Aumento do Rebordo Alveolar/métodos , Transplante Ósseo/métodos , Desenho Assistido por Computador , Implantação Dentária Endóssea/métodos , Desenho de Equipamento , Humanos , Masculino , Maxila/fisiologia , Pessoa de Meia-Idade , Titânio
20.
Proc Inst Mech Eng H ; 225(3): 296-302, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21485330

RESUMO

In this paper, the complete procedure to design and construct reusable moulds for implant-based ear prosthesis and manufacture substructures by means of a computer aided design-computer aided manufacturing (CAD-CAM) procedure and rapid prototyping (RP) technology is presented. The scan of the healthy ear, the virtual superimposition of its mirrored image on to the defective side, and the rapid manufacturing of the substructure and of the mould eliminate several steps of traditional procedures (wax, stone, try-in). Moreover, the precise design and customization of the substructure is presented, with the original and engineered shape for the retention of the silicone. The time and cost saving results of this protocol are presented together with a discussion of the main design features that make the prosthesis a stable and reproducible system to improve rehabilitation of patients with auricular defects or absence.


Assuntos
Engenharia Biomédica/métodos , Desenho Assistido por Computador , Orelha Externa/anatomia & histologia , Próteses e Implantes , Desenho de Prótese/métodos , Diagnóstico por Imagem , Humanos , Lasers , Modelos Anatômicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...